Abstract:
Field aligned starting (FAS) is a new technique for starting three-phase cage induction motors on single-phase supply lines with minimal inrush currents. It uses a simple energy storage system to generate a very high impulsive torque by which the motor is started before being connected to the mains supply. The spinning motor can then be connected to the mains to operate in a standard Steinmetz connection without incurring high inrush currents, if the moment of mains connection is properly timed. This paper presents a transient model and an accompanying parameter estimation method through which the transient behavior of three-phase induction motors operated with FAS can be analyzed. The proposed model is based on instantaneous symmetrical components and is used to investigate a 3 kWmotor started under various operating conditions. The proposed parameter estimation method and the developed transient model are both validated by experimental results.