Optimisation of a Real Time All Fibre Spectroscopic Fluorescence Probe

Show simple item record

dc.contributor.advisor Vanholsbeeck, F en
dc.contributor.author Kuo, Jason en
dc.date.accessioned 2012-03-08T01:52:09Z en
dc.date.issued 2012 en
dc.identifier.uri http://hdl.handle.net/2292/13408 en
dc.description Full text is available to authenticated members of The University of Auckland only. en
dc.description.abstract Bacteria can be used to aid bioremediation and it is crucial to monitor the bacteria involved to gain feedback on the effectiveness of the remediation process. To allow monitoring, these bacteria can be labelled with fluorescent proteins. The optrode setup is an all fibre real time spectroscopic setup which allows in situ measurements of the bacteria fluorescence emission spectrum. The measured spectra can then be used to quantify the amount of bacteria present. The aim of this thesis was to make improvements on the optrode setup, first by understanding how different fibre parameters such as the numerical aperture and core diameter affect the illumination volume of the fibre probe. Photon propagation is modelled by Monte Carlo simulations, allowing the laser illumination volume to be visualised and the intensity decrease of the beam profiles to be plotted. The choice of fibre to make the probes can be decided depending on specific applications. To increase the detection limit of the setup, variations in spectral shape and amplitude of the acquired spectra need to be minimised. Existing experiment protocols were examined to isolate how variations in spectrum are introduced, and also how they can be avoided. Before the bacteria population can be quantified, the acquired spectrum needs to be separated into individual spectral components when several bacteria are measured together. Existing deconvolution algorithms were reviewed and a new method utilising the open-source software Fityk and the Levenberg-Marquardt optimisation was tested as an attempt to make the deconvolution process more versatile and applicable to a wider range of spectral shapes. Results of the optrode setup monitoring bacteria distribution and concentration are also presented to demonstrate the how the optrode setup can be used for different biomedical applications. In this research, the more intricate details of the optrode setup were investigated. The items presented in this thesis provide additional information regarding potential improvements of the optrode setup. en
dc.publisher ResearchSpace@Auckland en
dc.relation.ispartof Masters Thesis - University of Auckland en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights Restricted Item. Available to authenticated members of The University of Auckland. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/nz/ en
dc.title Optimisation of a Real Time All Fibre Spectroscopic Fluorescence Probe en
dc.type Thesis en
thesis.degree.grantor The University of Auckland en
thesis.degree.level Masters en
dc.rights.holder Copyright: The author en
pubs.elements-id 314996 en
pubs.record-created-at-source-date 2012-03-08 en
dc.identifier.wikidata Q112890332


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics