The repeatability and variability of the multifocal electroretinogram for four different electrodes

Show simple item record

dc.contributor.author Mohidin, N en
dc.contributor.author Yap, Maurice en
dc.contributor.author Jacobs, Robert en
dc.date.accessioned 2013-01-10T03:47:07Z en
dc.date.issued 1997 en
dc.identifier.citation Ophthalmic and Physiological Optics 17(6):530-535 1997 en
dc.identifier.issn 0275-5408 en
dc.identifier.uri http://hdl.handle.net/2292/19844 en
dc.description.abstract Multifocal electroretinograms were recorded from twelve subjects on three separate days using the Visual Evoked Response Imaging System (VERIS). The subjects were 18–40 years-of-age. Each recording session was separated by an interval of between one and 16 weeks. Four electrode types were compared: the JET contact lens electrode, the gold foil electrode, the DTL thread electrode and the carbon fibre (c-glide) electrode. The b-wave amplitude density (nV/ sq.deg) recorded with each electrode was measured. The mean amplitude density recorded at each session for each subject and each electrode was calculated and compared. There were no significant differences in amplitude density for the ERGs recorded with each type of electrode over the three days. The coefficient of variation for each electrode and each subject was then calculated using the results for the three days. The coefficients of variation for each electrode showed significant differences (One-way ANOVA: F=4.51. d.f. =3, 44. P < 0.008). The c-glide electrode results had the highest variability and post hoc tests showed that its coefficient of variation was significantly different from those of the JET and gold foil electrodes but not from that of the DTL thread electrode. en
dc.publisher John Wiley & Sons, Inc. en
dc.relation.ispartofseries Ophthalmic and Physiological Optics en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained http://www.sherpa.ac.uk/romeo/issn/0275-5408/ en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title The repeatability and variability of the multifocal electroretinogram for four different electrodes en
dc.type Journal Article en
dc.identifier.doi 10.1046/j.1475-1313.1997.97000343.x en
pubs.issue 6 en
pubs.begin-page 530 en
pubs.volume 17 en
dc.rights.holder Copyright: The College of Optometrists en
dc.identifier.pmid 9666928 en
pubs.end-page 535 en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Article en
pubs.elements-id 10019 en
pubs.org-id Medical and Health Sciences en
pubs.org-id Optometry and Vision Science en
pubs.record-created-at-source-date 2010-09-01 en
pubs.dimensions-id 9666928 en


Files in this item

There are no files associated with this item.

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics