Experimental pull-out test program of wall-to-diaphragm adhesive connections and observations from 2010/2011 Canterbury earthquakes

Show simple item record

dc.contributor.author Dizhur, Dmytro en
dc.contributor.author Ingham, Jason en
dc.contributor.author Campbell, J en
dc.contributor.author Schultz, A en
dc.coverage.spatial Wellington en
dc.date.accessioned 2013-05-09T02:24:15Z en
dc.date.issued 2013-04-26 en
dc.identifier.citation 2013 NZSEE Conference, Wellington, 26 Apr 2013 - 28 Apr 2013. 12 pages en
dc.identifier.uri http://hdl.handle.net/2292/20477 en
dc.description.abstract The connections between walls of unreinforced masonry (URM) buildings and flexible timber diaphragms are critical building components that must perform adequately before desirable earthquake response of URM buildings may be achieved. Field observations made during the initial reconnaissance and the subsequent damage surveys of clay brick URM buildings following the 2010/2011 Canterbury, New Zealand earthquakes revealed numerous cases where anchor connections joining masonry walls or parapets with roof or floor diaphragms appeared to have failed prematurely. These observations were more frequent for adhesive anchor connections than for through-bolt connections (i.e. anchorages having plates on the exterior façade of the masonry walls). Subsequently, an in-field test program was undertaken in an attempt to evaluate the performance of adhesive anchor connections between unreinforced clay brick URM walls and roof or floor diaphragm. The study consisted of a total of almost 400 anchor tests conducted in eleven existing URM buildings located in Christchurch, Whanganui and Auckland. Specific objectives of the study included the identification of failure modes of adhesive anchors in existing URM walls and the influence of the following variables on anchor load-displacement response: adhesive type, strength of the masonry materials (brick and mortar), anchor embedment depth, anchor rod diameter, overburden level, anchor rod type, quality of installation and the use of metal mesh sleeve. In addition, the comparative performance of bent anchors (installed at an angle of minimum 22.5o to the perpendicular projection from the wall surface) and anchors positioned horizontally was investigated. Observations on the performance of wall-to-diaphragm connections in the 2010/2011 Canterbury earthquakes, a snapshot of the performed experimental program and the test results and a preliminary proposed pull-out capacity of adhesive anchors are presented herein. en
dc.description.uri http://www.confer.co.nz/nzsee/ en
dc.relation.ispartof 2013 NZSEE Conference en
dc.relation.ispartofseries Proceedings of the 2013 NZSEE Conference en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Experimental pull-out test program of wall-to-diaphragm adhesive connections and observations from 2010/2011 Canterbury earthquakes en
dc.type Conference Item en
dc.description.version VoR - Version of Record en
pubs.author-url http://www.nzsee.org.nz/db/2013/Poster_53.pdf en
pubs.finish-date 2013-04-28 en
pubs.publication-status Published en
pubs.start-date 2013-04-26 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Proceedings en
pubs.elements-id 379718 en
pubs.org-id Engineering en
pubs.org-id Civil and Environmental Eng en
pubs.record-created-at-source-date 2013-05-08 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics