An anatomically based mathematical model of the human lungs, applied to gas mixing and water vapour and heat transport

ResearchSpace/Manakin Repository

Show simple item record

dc.contributor.advisor Hunter, Peter en
dc.contributor.advisor Pullan, Andrew en
dc.contributor.author Tawhai, Merryn Howatson en
dc.date.accessioned 2008-01-16T01:57:53Z en
dc.date.available 2008-01-16T01:57:53Z en
dc.date.issued 2001 en
dc.identifier THESIS 2005-B97 en
dc.identifier.uri http://hdl.handle.net/2292/2301 en
dc.description Full text is available to authenticated members of The University of Auckland only. en
dc.description.abstract This thesis has focused on developing an anatomically-based model of the human lungs, initially to be used for modelling transport problems. An algorithm is presented for generating three-dimensional conducting airway models into anatomically-based host volumes. The algorithm uses a bifurcating distributive method to generate a three-dimensional tree that fills an anatomically based pleural cavity. Branching, length, and diameter ratios from the generated model are consistent with experimental results, and the mean branch angles are consistent with a theoretical 'ideal' angle. The proportion and number of branches in each of the five model lobes are similar to those from the literature. A lumped parameter model for respiratory airway gas mixing is developed, based on results from gas mixing in a multi-branching model. Development of a computationally small respiratory airway model for coupling to the asymmetric conducting airway model is necessary to ensure that solution of transport equations in the coupled model are feasible. The lumped parameter model is calibrated using gas mixing results from an anatomically-based multi-branching respiratory airway model, over a wide range of simulation conditions and model sizes. The lumped parameter model is in the form of regression equations that are used to predict transitional bronchiole concentrations throughout expiration, based on inspiratory parameters that are particular to each coupled lumped parameter model. The lumped parameter respiratory airway model is coupled with the asymmetric conducting airway model to simulate gas mixing in the entire lung system. Results from full lung gas mixing show the importance of respiratory airway asymmetry and incomplete mixing, conducting airway asymmetry, blood gas exchange, and airway mechanics, on generation of a sloping alveolar plateau in phase I11 of the washout curve. Respiratory airway asymmetry and incomplete mixing is shown to have the greatest contribution to S, (the slope of the alveolar plateau normalised by the mean expired gas concentration) in the first breaths of multiple washin tests. Conducting airway asymmetry is shown to increase S, in a manner consistent with the literature, even when flow is distributed uniformly throughout the model. Blood gas exchange moderates the S, curve such that the plot of S, against breath number approaches a plateau after approximately 18 breaths. Airway mechanics are represented in this study by idealised pleural pressure gradients. The pleural pressure gradients are shown to have a complex effect on S,. This study highlights the import contribution made by each of these factors to generation of S, over multiple breaths. A model of water and heat exchange in the asymmetric conducting airway model is developed for investigating penetration of the airways by unconditioned gas, and for investigating airway drying. The water and heat transfer model incorporates radial layers of airway surface liquid, sub-mucosa/tissue, and a surrounding capillary bed. Additional layers can be included in the model to simulate an endotracheal tube and associated condensation. Unlike other models in the literature, the respiratory transfer model presented in this study uses power law curves to describe the velocity,temperature, and concentration across an airway. The model therefore solves coupled transport and transfer equations both axially and radially. The transfer of water vapour or heat is governed by the concentration and temperature gradients at the interface between the surface liquid and the air in the lumen: empirically derived transfer coefficients are not used to predict heat and mass transfer in this model.Comparison of results from the water and heat transfer model with experimental results shows that the model presented in this study produces airway temperatures close to experimental measurements for ventilation up to 60 L .rnin-' with an inspired temperature of 30.3"C. For combined higher ventilation rates and lower temperatures the model does not sustain sufficient wall cooling during inspiration. The model simulates temperatures down an endotracheal tube that are close in value to experimental temperatures. Airway drying in the model is shown to be dependent on the rate of replenishment of the airway surface liquid by the surrounding tissue. en
dc.language.iso en en
dc.publisher ResearchSpace@Auckland en
dc.relation.ispartof PhD Thesis - University of Auckland en
dc.relation.isreferencedby UoA9995157514002091 en
dc.rights Restricted Item. Available to authenticated members of The University of Auckland. en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title An anatomically based mathematical model of the human lungs, applied to gas mixing and water vapour and heat transport en
dc.type Thesis en
thesis.degree.discipline Engineering Science en
thesis.degree.grantor The University of Auckland en
thesis.degree.level Doctoral en
thesis.degree.name PhD en
dc.subject.marsden Fields of Research::290000 Engineering and Technology::291500 Biomedical Engineering en
dc.rights.holder Copyright: The author en
pubs.org-id Bioengineering Institute en


Full text options

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Advanced Search

Browse