Effects of unreinforced masonry wall slenderness ratio on out-of-plane post-cracking dynamic stability

Show simple item record

dc.contributor.author Derakhshan, Hossein en
dc.contributor.author Ingham, Jason en
dc.contributor.author Griffith, Michael en
dc.contributor.editor Jason Ingham en
dc.coverage.spatial Wellington en
dc.date.accessioned 2015-02-09T03:18:03Z en
dc.date.issued 2010 en
dc.identifier.citation Proceedings of the 2010 NZSEE Annual Conference, 2010, pp. 1 - 8 en
dc.identifier.uri http://hdl.handle.net/2292/24431 en
dc.description.abstract A large number of time-history analyses were performed on several unreinforced masonry (URM) walls that had different slenderness ratios, and the viability of adopting wall slenderness ratio as a criterion for seismic assessment was investigated. Several combinations of three wall properties were assumed to cover most walls found in New Zealand URM buildings, and 30 representative time-history records were used to perform analyses. Walls were either two-leaf thick with no overburden load applied or three-leaf thick having an overburden load applied equal to the weight of a typical second-storey two-leaf URM wall. Wall behavioural data was obtained based on a previous laboratory based study, and each wall was subjected to ground motion scenarios with increasing peak ground acceleration (PGA). The ground motion record PGA that caused the wall to undergo a displacement limit equal to 60% of wall instability displacement was identified, and the sensitivity of the obtained PGA to wall slenderness ratio was studied for all the used records. It was shown that increasing wall slenderness ratio resulted in the wall being more vulnerable. en
dc.relation.ispartof 2010 NZSEE Annual Conference en
dc.relation.ispartofseries Proceedings of the 2010 NZSEE Annual Conference en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Effects of unreinforced masonry wall slenderness ratio on out-of-plane post-cracking dynamic stability en
dc.type Conference Item en
pubs.begin-page 1 en
dc.description.version VoR - Version of Record en
pubs.author-url http://www.nzsee.org.nz/db/2010/Paper55.pdf en
pubs.end-page 8 en
pubs.finish-date 2010-03-28 en
pubs.start-date 2010-03-26 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Proceedings en
pubs.elements-id 101840 en
pubs.org-id Engineering en
pubs.org-id Civil and Environmental Eng en
pubs.record-created-at-source-date 2010-09-01 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics