Increased Range of Ultrasonic Guided Wave Testing of Overhead Transmission Line Cables using Dispersion Compensation

Show simple item record

dc.contributor.author Legg, Mathew en
dc.contributor.author Yücel, MK en
dc.contributor.author Kappatos, V en
dc.contributor.author Selcuk, C en
dc.contributor.author Gan, T-H en
dc.date.accessioned 2015-08-17T05:14:56Z en
dc.date.issued 2015 en
dc.identifier.citation Ultrasonics, 2015, 62 pp. 35 - 45 en
dc.identifier.issn 0041-624X en
dc.identifier.uri http://hdl.handle.net/2292/26751 en
dc.description.abstract Overhead Transmission Line (OVTL) cables can experience structural defects and are, therefore, inspected using Non-Destructive Testing (NDT) techniques. Ultrasonic Guided Waves (UGW) is one NDT technique that has been investigated for inspection of these cables. For practical use, it is desirable to be able to inspect as long a section of cable as possible from a single location. This paper investigates increasing the UGW inspection range on Aluminium Conductor Steel Reinforced (ACSR) cables by compensating for dispersion using dispersion curve data. For ACSR cables, it was considered to be difficult to obtain accurate dispersion curves using modelling due to the complex geometry and unknown coupling between wire strands. Group velocity dispersion curves were, therefore, measured experimentally on an untensioned, 26.5 meter long cable and a method of calculating theoretical dispersion curves was obtained. Attenuation and dispersion compensation were then performed for a broadband Maximum Length Sequence (MLS) excitation signal. An increase in the Signal to Noise Ratio (SNR) of about 4 to 8 dB compared to that of the dispersed signal was obtained. However, the main benefit was the increased ability to resolve the individual echoes from the end of the cable and an introduced defect in the form of a cut, which was 7 to at least 13 dB greater than that of the dispersed signal. Five echoes were able to be clearly detected using MLS excitation signal, indicating the potential for an inspection range of up to 130 meters in each direction. To the best of the authors knowledge, this is the longest inspection range for ACSR cables reported in the literature, where typically cables, which were only one or two meter long, have been investigated previously. Narrow band tone burst and Hann windowed tone burst excitation signal also showed increased SNR and ability to resolve closely spaced echoes. en
dc.publisher Elsevier en
dc.relation.ispartofseries Ultrasonics en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained from http://www.sherpa.ac.uk/romeo/issn/0041-624X/ en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Increased Range of Ultrasonic Guided Wave Testing of Overhead Transmission Line Cables using Dispersion Compensation en
dc.type Journal Article en
dc.identifier.doi 10.1016/j.ultras.2015.04.009 en
pubs.begin-page 35 en
pubs.volume 62 en
dc.description.version AM - Accepted Manuscript en
dc.rights.holder Copyright: Elsevier en
pubs.author-url http://dx.doi.org/10.1016/j.ultras.2015.04.009 en
pubs.end-page 45 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Article en
pubs.elements-id 486976 en
dc.identifier.eissn 1874-9968 en
pubs.record-created-at-source-date 2015-05-11 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics