Deformation response of adhesive anchors in retrofitted masonry structures during the 2010/2011 Canterbury, New Zealand earthquakes

Show simple item record

dc.contributor.author Schultz, AE en
dc.contributor.author Dizhur, Dmytro en
dc.contributor.author Ingham, Jason en
dc.coverage.spatial London, England en
dc.date.accessioned 2015-11-04T03:53:41Z en
dc.date.issued 2014 en
dc.identifier.citation Structural Faults & Repair 2014, London, England, 08 Jul 2014 - 10 Jul 2014. Proceedings, Structural Faults & Repair 2014 en
dc.identifier.uri http://hdl.handle.net/2292/27392 en
dc.description.abstract Between September 4, 2010 and December 23, 2011, a series of earthquakes struck the South Island of New Zealand including the city of Christchurch producing heavy damage. During the strongest shaking, the unreinforced masonry (URM) building stock in Christchurch was subjected to seismic loading equal to approximately 150-200% of code values. Post-earthquake reconnaissance suggested numerous failures of adhesive anchors used for retrofit connection of roof and floor diaphragms to masonry walls. A team of researchers from the Universities of Auckland (NZ) and Minnesota (USA) conducted a field investigation on the performance of new adhesive anchors installed in existing masonry walls. Variables included adhesive type, anchor diameter, embedment length, anchor inclination, and masonry quality. Buildings were selected that had been slated for demolition but which featured exterior walls that had not been damaged. A summary of the deformation response measured during the field tests are presented. en
dc.relation.ispartof Structural Faults & Repair 2014 en
dc.relation.ispartofseries Proceedings, Structural Faults & Repair 2014 en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.subject Adhesive Anchors en
dc.subject Field Tests en
dc.subject Seismic Performance en
dc.subject Unreinforced Masonry en
dc.title Deformation response of adhesive anchors in retrofitted masonry structures during the 2010/2011 Canterbury, New Zealand earthquakes en
dc.type Conference Item en
dc.description.version AM - Accepted Manuscript en
pubs.finish-date 2014-07-10 en
pubs.start-date 2014-07-08 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Proceedings en
pubs.elements-id 502100 en
pubs.org-id Engineering en
pubs.org-id Civil and Environmental Eng en
pubs.record-created-at-source-date 2015-10-19 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics