In-plane and out-of-plane testing of unreinforced masonry walls strengthened using polymer textile reinforced mortar

Show simple item record

dc.contributor.author Ismail, N en
dc.contributor.author Ingham, Jason en
dc.date.accessioned 2016-06-16T00:46:53Z en
dc.date.issued 2016-07-01 en
dc.identifier.citation Engineering Structures, 2016, 118 pp. 167 - 177 en
dc.identifier.issn 0141-0296 en
dc.identifier.uri http://hdl.handle.net/2292/29090 en
dc.description.abstract Details of an experimental program investigating the structural performance of unreinforced masonry (URM) walls strengthened using two different types of polymer textile reinforced mortar (TRM) is presented. The experimental program involved full scale reversed cyclic in-plane and out-of-plane testing of TRM strengthened URM walls. The testing was performed in two series, with series 1 involving in-plane testing of two (03) pier-spandrel assemblages representing part of a perforated URM wall and series 2 involving out-of-plane testing of three (03) slender walls having no penetrations. To replicate the physical characteristics of historic masonry materials, vintage solid clay bricks and a low strength hydraulic cement mortar were used for construction of the test walls. Numerous structural characteristics pertaining to the seismic behaviour of TRM strengthened historic URM walls were investigated and then compared to those obtained from corresponding as-built tested URM walls. In general, strengthened walls exhibited a ductile behaviour until the polymer textile ruptured in a brittle manner. The strength increment due to TRM strengthening was observed to range from 128% to 136% when the URM test walls were loaded in-plane and from 575% to 786% when the URM test walls were loaded out-of-plane, with a notable increment in deformation capacity and ductility. en
dc.relation.ispartofseries Engineering Structures en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained from http://www.sherpa.ac.uk/romeo/issn/0141-0296/ en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/ en
dc.title In-plane and out-of-plane testing of unreinforced masonry walls strengthened using polymer textile reinforced mortar en
dc.type Journal Article en
dc.identifier.doi 10.1016/j.engstruct.2016.03.041 en
pubs.begin-page 167 en
pubs.volume 118 en
dc.description.version AM - Accepted Manuscript en
pubs.end-page 177 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Article en
pubs.elements-id 526457 en
pubs.org-id Engineering en
pubs.org-id Civil and Environmental Eng en
dc.identifier.eissn 1873-7323 en
pubs.record-created-at-source-date 2016-06-16 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics