A Robust and Reliable Test to Measure Stereopsis in the Clinic

Show simple item record

dc.contributor.author Hess, RF en
dc.contributor.author Ding, R en
dc.contributor.author Clavagnier, S en
dc.contributor.author Liu, C en
dc.contributor.author Guo, Xiaopeng en
dc.contributor.author Viner, C en
dc.contributor.author Barrett, BT en
dc.contributor.author Radia, K en
dc.contributor.author Zhou, J en
dc.date.accessioned 2016-09-28T02:10:01Z en
dc.date.issued 2016-03 en
dc.identifier.citation Investigative Ophthalmology and Visual Science 57(3):798-804 Mar 2016 en
dc.identifier.issn 0146-0404 en
dc.identifier.uri http://hdl.handle.net/2292/30515 en
dc.description.abstract The purpose of this study was to develop a convenient test of stereopsis in the clinic that is both robust and reliable and capable of providing a measure of variability necessary to make valid comparisons between measurements obtained at different occasions or under different conditions.Stereo acuity was measured based on principles derived from the laboratory measurement of stereopsis (i.e., staircase method). Potential premeasurement compensations are described if there is a significant degree of ocular misalignment, reduced visual acuity, or aniseikonia. Forty-six adults at McGill University, 44 adults at Auckland University, and 51 adults from the University of Bradford, with an age range of 20 to 65 years old and normal or corrected-to-normal vision participated in this study.Stereo acuity within this normal population was widely distributed, with a significant percentage (28%) of the population with only coarse stereo (>300 arc seconds). Across subjects, the SD was approximately 25% of the mean. Measurements at two different times were strongly (r = 0.79) and significantly (P < 0.001) correlated, with little to no significant (P = 0.79) bias (0.01) between test and retest measures of stereopsis.The application enables measurements over the wide disparity range and not just at the finest disparities. In addition, it allows changes in stereopsis of the order of 1.9 to be statistically distinguished. en
dc.format.medium Print en
dc.language eng en
dc.publisher Association for Research in Vision and Ophthalmology (ARVO) en
dc.relation.ispartofseries Investigative Ophthalmology and Visual Science en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained from http://www.sherpa.ac.uk/romeo/issn/0146-0404/ en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/ en
dc.title A Robust and Reliable Test to Measure Stereopsis in the Clinic en
dc.type Journal Article en
dc.identifier.doi 10.1167/iovs.15-18690 en
pubs.issue 3 en
pubs.begin-page 798 en
pubs.volume 57 en
dc.description.version VoR - Version of Record en
dc.rights.holder Copyright: The authors en
dc.identifier.pmid 26934135 en
pubs.end-page 804 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Article en
pubs.elements-id 525305 en
dc.identifier.eissn 1552-5783 en
pubs.record-created-at-source-date 2016-09-28 en
pubs.dimensions-id 26934135 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics