Simple and versatile long range swept source for optical coherence tomography applications

Show simple item record

dc.contributor.author Bräuer, B en
dc.contributor.author Lippok, N en
dc.contributor.author Murdoch, Stuart en
dc.contributor.author Vanholsbeeck, Frederique en
dc.date.accessioned 2017-02-16T02:38:13Z en
dc.date.available 2015-09-17 en
dc.date.issued 2015-10-27 en
dc.identifier.citation Journal of Optics, 27 October 2015, 17 (12), Article number 125301 en
dc.identifier.issn 2040-8978 en
dc.identifier.uri http://hdl.handle.net/2292/31854 en
dc.description.abstract We present a versatile long coherence length swept-source laser design for optical coherence tomography applications. This design consists of a polygonal spinning mirror and an optical gain chip in a modified Littman–Metcalf cavity. A narrowband intra-cavity filter is implemented through multiple passes off a diffraction grating set at grazing incidence. The key advantage of this design is that it can be readily adapted to any wavelength regions for which broadband gain chips are available. We demonstrate this by implementing sources at 1650 nm, 1550 nm, 1310 nm and 1050 nm. In particular, we present a 1310 nm swept source laser with 24 mm coherence length, 95 nm optical bandwidth, 2 kHz maximum sweep frequency and 7.5 mW average output power. These parameters make it a suitable source for the imaging of biological samples. en
dc.language English en
dc.publisher IOP - Institute of Physics en
dc.relation.ispartofseries Journal of Optics en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained from http://www.sherpa.ac.uk/romeo/issn/2040-8978/ http://iopscience.iop.org/info/page/openaccess en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.rights.uri https://creativecommons.org/licenses/by/3.0/ en
dc.title Simple and versatile long range swept source for optical coherence tomography applications en
dc.type Journal Article en
dc.identifier.doi 10.1088/2040-8978/17/12/125301 en
pubs.issue 12 en
pubs.volume 17 en
dc.description.version VoR - Version of Record en
pubs.author-url http://iopscience.iop.org/article/10.1088/2040-8978/17/12/125301 en
pubs.publication-status Published en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Article en
pubs.elements-id 510552 en
pubs.org-id Science en
pubs.org-id Physics en
dc.identifier.eissn 2040-8986 en
pubs.number 125301 en
pubs.record-created-at-source-date 2017-02-16 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics