Pressure Drop in Large Diameter Geothermal Two-Phase Pipelines

Show simple item record

dc.contributor.author rizaldy en
dc.contributor.author Zarrouk, Sadiq en
dc.coverage.spatial Auckland, New Zealand en
dc.date.accessioned 2017-04-05T23:41:04Z en
dc.date.issued 2016 en
dc.identifier.citation 38th New Zealand Geothermal Workshop, Auckland, New Zealand, 23 Nov 2016 - 25 Nov 2016 en
dc.identifier.uri http://hdl.handle.net/2292/32474 en
dc.description.abstract Most conventional geothermal wells produce two-phase flow of water, steam and gas at the well head. This fluid normally travels at the surface in the geothermal fluid transmission system toward the separator where steam and water are separated. Early transmission system used short runs of small diameter pipelines to avoid the slug flow regime, which caused significant problems of increased pressure drop and water hammer effects to the pipelines. However, significant work was been dedicated over the years to develop and use empirical, theoretical and phenomenological correlations to calculate pressure drop in the two-phase pipelines. However, most of these correlations were developed from work on relatively small diameter pipelines. As most of the new geothermal development uses large diameter pipelines carrying fluid from several wells to centralized separation stations, problems have been encountered in many fields. This work evaluates some of the existing correlations for estimating pressure drop in two-phase geothermal pipelines applied to field data from the Lahendong geothermal field, Indonesia. Actual two-phase pressure drop data were measured from a range of horizontal pipes (10-22“) to be compared with the existing correlations. The result shows that the annular flow is the most common flow regime in the pipelines. Generally, Friedel’s correlation is the best suited for large diameter (>18“) pipelines, with 5–15% average deviation. The homogenous and Harrison-Freeston methods better suit smaller pipe sizes (10”–18”), with an average deviation of 5–28%. The Lockhart-Martinelli, Zhao-Freeston and Brill-Mukherjee correlations were found to be less accurate in predicting the two-phase pressure drop in the same range of pipe sizes. Based on the results, a correction factors chart is proposed to reduce discrepancies in the estimated pressure drops for the given range of pipe sizes. en
dc.description.uri http://www.geothermalworkshop.co.nz/programme/ en
dc.relation.ispartof 38th New Zealand Geothermal Workshop en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Pressure Drop in Large Diameter Geothermal Two-Phase Pipelines en
dc.type Conference Item en
dc.description.version VoR - Version of Record en
pubs.author-url https://www.geothermal-energy.org/pdf/IGAstandard/NZGW/2016/065_Rizaldy_Final.pdf en
pubs.finish-date 2016-11-25 en
pubs.start-date 2016-11-23 en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Proceedings en
pubs.elements-id 552396 en
pubs.org-id Engineering en
pubs.org-id Engineering Science en
pubs.record-created-at-source-date 2016-12-12 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics