Ultrasound imaging of the distal radioulnar joint: a new method to assess ulnar radial translation in forearm rotation

Show simple item record

dc.contributor.author Oldfield, CE en
dc.contributor.author Boland, Michael en
dc.contributor.author Greybe, Desney en
dc.contributor.author Hing, W en
dc.date.accessioned 2017-06-21T05:34:02Z en
dc.date.issued 2017-05 en
dc.identifier.citation Journal of Hand Surgery (European Volume) 42(4):389-394 May 2017 en
dc.identifier.issn 1753-1934 en
dc.identifier.uri http://hdl.handle.net/2292/33691 en
dc.description.abstract A cross-sectional reliability study was conducted with 23 normal participants to establish normal values, and the repeatability and validity of distal radioulnar joint translation measurements using ultrasound imaging. Static transverse images of maximal supination, neutral and maximal pronation were examined to assess translation, using a method consistent with the rheumatoid arthritis subluxation ratio. Translation while gripping a 1 kg weight in supinated and pronated positions was then compared with non-gripping translation. There was significantly more ulnar radial translation found with pronation than supination, when compared with neutral. Gripping in pronation did not produce statistically significant changes in translation, whereas the changes produced by gripping in supination were significant. Internal consistency was deemed very high and the rheumatoid arthritis subluxation ratio values measured using ultrasound imaging were consistent with previously documented values measured by computerized tomography. This study demonstrated that translational movement of the distal radioulnar joint can be reliably detected in healthy participants using ultrasound imaging. This may reduce dependency on other imaging modalities to diagnose distal radioulnar joint instability. en
dc.format.medium Print-Electronic en
dc.language eng en
dc.publisher Sage Publications en
dc.relation.ispartofseries Journal of Hand Surgery (European Volume) en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Ultrasound imaging of the distal radioulnar joint: a new method to assess ulnar radial translation in forearm rotation en
dc.type Journal Article en
dc.identifier.doi 10.1177/1753193416640464 en
pubs.issue 4 en
pubs.begin-page 389 en
pubs.volume 42 en
dc.rights.holder Copyright: Sage Publications en
dc.identifier.pmid 27165981 en
pubs.end-page 394 en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Article en
pubs.elements-id 527673 en
dc.identifier.eissn 2043-6289 en
pubs.record-created-at-source-date 2017-06-21 en
pubs.dimensions-id 27165981 en


Files in this item

There are no files associated with this item.

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics