dc.description.abstract Grouted connections are widely used to connect precast concrete wall panels to their foundations. Various forms of grouted inserts are utilised in different countries to provide a splice between the wall panel and the connection reinforcement. A commonly used coupler insert in New Zealand is grouted sleeve inserts. This type of inserts has a threaded portion on top of the insert to connect the panel reinforcement and a tube-shaped part for positioning and anchoring connection reinforcement using cementitious grout. The two concerns associated with this type of connections are thread slip and reinforcement pull-out from the grout when the inserted reinforcement is subjected to cyclic loads. Thread slip affects the panel stiffness and reduces the connection integrity, and reinforcement pull-out is an undesirable failure mode. In order to evaluate the force-displacement behaviour of connections with grouted sleeve connectors, two full-scale experiments were conducted with one wall panel being reinforced with a single layer of vertical reinforcing and the other wall panel being doubly reinforced. The geometry and detailing of the wall panels was based on a previously conducted review of over 4000 constructed precast concrete wall panels. The specimens were subjected to reverse in-plane cycle loads until failure of either the connection or the wall panel. The results of the experiments are discussed in this article. en
dc.description.uri http://db.nzsee.org.nz/2017/Orals.htm en
dc.relation.ispartof 2017 NZSEE Conference en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title In-plane testing of precast concrete wall panels with grout sleeves en
dc.type Conference Item en
pubs.begin-page 1 en
pubs.author-url http://db.nzsee.org.nz/2017/O2A.2_Seifi.pdf en
pubs.end-page 8 en
pubs.finish-date 2017-04-29 en
pubs.publication-status Published en
pubs.start-date 2017-04-27 en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Conference Paper en
pubs.elements-id 624101 en
pubs.org-id Engineering en
pubs.org-id Civil and Environmental Eng en
pubs.record-created-at-source-date 2017-05-03 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics