Automated Optokinetic Nystagmus Detection for Use with Young Subjects

Show simple item record

dc.contributor.advisor Turuwhenua, J en
dc.contributor.advisor Thompson, B en
dc.contributor.author Sangi, Mehrdad en
dc.date.accessioned 2017-10-15T23:47:01Z en
dc.date.issued 2017 en
dc.identifier.uri http://hdl.handle.net/2292/36063 en
dc.description.abstract There are currently no objective tests of visual function for young children and the tests that do exist are subjective, can only be applied reliably in children over 3 years of age and require high levels of specialist clinical training. To overcome these problems, we have developed a low cost, portable, clinically applicable system that assesses visual function by inducing and measuring an involuntary, reflexive eye movement known as optokinetic nystagmus (OKN). This eye movement only occurs when a moving target is visible. First, we developed a novel semi-automated method for OKN detection able to separate eye movements from the raw head/eye signal using stabilization of the eye region. The stabilization method was validated using direct subtraction of head motions from combined head-eye movements. The detection of OKN-like peaks agreed well with subjective judgements provided by an experienced observer (accuracy=85%). Secondly, we assessed whether frame rates achievable with a low cost commercially available camera were sufficient to measure key parameters of OKN. We used a webcam (30 Hz) and a research grade eye tracker (420 Hz) to record OKN in 10 adults. Downsampling was used to simulate eye tracker data at 30, 60, 120, 240 Hz. We found that for OKN detection, there was no need to use high frame rate cameras, but for accurate measurement of OKN parameters higher frame rate (an average of 255 Hz) was required. Finally, we applied our methods to provide a fully automated estimation of global motion coherence thresholds. We combined our existing methods with the Visage SDK head and eye tracking software (Visage SDK). The improved automated OKN detection system was used as an objective method for estimation of global motion coherence thresholds in 20 two-year old children. We found good agreement between the objective and subjective (gold standard) measurements of global motion coherence threshold (83.01% 10.45% and 83.36 11.90% respectively). Overall, we found that OKN detection does not require any calibration procedures, head rests or special hardware. Our new algorithms could be a core component of a device that provides measures of visual functions such as visual acuity, contrast sensitivity and global motion coherence in children as young as two years old. en
dc.publisher ResearchSpace@Auckland en
dc.relation.ispartof PhD Thesis - University of Auckland en
dc.relation.isreferencedby UoA99265059913202091 en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Automated Optokinetic Nystagmus Detection for Use with Young Subjects en
dc.type Thesis en
thesis.degree.discipline Bioengineering en
thesis.degree.grantor The University of Auckland en
thesis.degree.level Doctoral en
thesis.degree.name PhD en
dc.rights.holder Copyright: The author en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.elements-id 693906 en
pubs.org-id Bioengineering Institute en
pubs.record-created-at-source-date 2017-10-16 en
dc.identifier.wikidata Q112932757


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics