dc.description.abstract Implantable medical devices are recommended by physicians to sustain life while improving the overall quality of life of the patients. In spite of the rigorous testing, there have been numerous failures and associated recalls which suggest that completeness of the testing is elusive. We propose a new validation framework based on formal methods for real-time closed-loop validation of medical devices. The proposed approach includes a synchronous observer acting both as an automated oracle and also as a requirements coverage monitor. The observer combines an on-line testing adequacy evaluation module together with a heuristic learning module. This methodology was applied to validate a pacemaker over a virtual heart model. A subset of the requirements was used to test its efficacy. The results show that the proposed methodology can, in real-time, evaluate the test adequacy and hence guide the on-line test case generation to maximize the requirements coverage. en
dc.publisher IEEE en
dc.relation.ispartof Design, Automation and Test in Europe Conference and Exhibition (DATE) en
dc.relation.ispartofseries Proceedings of the 2016 Design, Automation and Test in Europe Conference and Exhibition (DATE) en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.subject Science & Technology en
dc.subject Technology en
dc.subject Automation & Control Systems en
dc.subject Engineering, Electrical & Electronic en
dc.subject Engineering en
dc.subject VERIFICATION en
dc.subject MODEL en
dc.title Requirements-centric closed-loop validation of implantable cardiac devices en
dc.type Conference Item en
pubs.begin-page 846 en
dc.rights.holder Copyright: The author en
pubs.author-url https://ieeexplore.ieee.org/document/7459426 en
pubs.end-page 849 en
pubs.finish-date 2016-03-18 en
pubs.publication-status Published en
pubs.start-date 2016-03-14 en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Proceedings en
pubs.elements-id 532265 en
pubs.org-id Engineering en
pubs.org-id Department of Electrical, Computer and Software Engineering en
pubs.record-created-at-source-date 2019-02-08 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics