The use of accelerometer-based navigation for coronal TKA alignment: a prospective, single surgeon comparative study

Show simple item record

dc.contributor.author Zhu, M en
dc.contributor.author Lindsay, E en
dc.contributor.author Keenan, A en
dc.contributor.author Munro, Jacob en
dc.contributor.author Monk, Andrew en
dc.date.accessioned 2020-09-30T01:25:46Z en
dc.date.available 2020-09-30T01:25:46Z en
dc.date.issued 2019-11-27 en
dc.identifier.issn 0936-8051 en
dc.identifier.uri http://hdl.handle.net/2292/53144 en
dc.description.abstract INTRODUCTION:There is the need for a device that can be used to accurately position components during total knee arthroplasty (TKA) with minimal impact on procedure time, workflow and cost. This study aimed to investigate the accuracy and time efficiency of a novel, accelerometer-based navigation system (ABN). METHODS:This prospective, single surgeon study of patients undergoing TKA for osteoarthritis over a 5 year period involved a total of 138 patients: 110 using the ABN system and 28 without. The ABN system consists of two coupled inertial pods that are secured to resection guides, providing a body-fixed 3D coordinate system for limb segments. Post-operative coronal alignment was measured from standardised long-leg AP radiographs. Deviation of the femur and tibia from the neutral coronal mechanical axis was recorded. Intra-observer repeatability was performed on three independent blinded data sets. The BMI and the surgical time (skin to skin) were recorded for all patients. RESULTS:The mean BMI was 34 in the ABN group and 33 in the control group (p = 0.92). The skin-to-skin time was also similar between the groups; 105 min in the navigation group and 100 min in the control group (p = 0.297). The use of navigation resulted in significantly fewer outliers as defined by < 3º deviation from the target angle. 3 of 110 navigated patients recorded an AP femur angle of more than 3º from the target of 90º, where 5 of 28 control patients fell outside of the ± 3º window (p = 0.009, Fig. 1). CONCLUSION:The use of the ABN system significantly improved accuracy of implant position and alignment without increasing surgical time. en
dc.publisher Springer (part of Springer Nature) en
dc.relation.ispartofseries Archives of Orthopaedic and Trauma Surgery en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title The use of accelerometer-based navigation for coronal TKA alignment: a prospective, single surgeon comparative study en
dc.type Journal Article en
dc.identifier.doi 10.1007/s00402-019-03295-4 en
dc.rights.holder Copyright: The author en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Article en
pubs.elements-id 809585 en
pubs.org-id Bioengineering Institute en
pubs.org-id Medical and Health Sciences en
pubs.org-id School of Medicine en
pubs.org-id Surgery Department en
pubs.record-created-at-source-date 2020-08-02 en
pubs.online-publication-date 2019-11-27 en
pubs.dimensions-id 31776659 en


Files in this item

There are no files associated with this item.

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics