New Foundations for Pacing the Stomach

Show simple item record

dc.contributor.advisor Paskaranandavadivel, Nira
dc.contributor.advisor Cheng, Leo K.
dc.contributor.author Alighaleh, Saeed
dc.date.accessioned 2021-01-07T23:57:30Z
dc.date.available 2021-01-07T23:57:30Z
dc.date.issued 2020 en
dc.identifier.uri https://hdl.handle.net/2292/54097
dc.description.abstract The use of electrical pacing and high-resolution (HR) mapping continues to advance our understanding of gut motility in health and disease. However, the efficacy and effectiveness of gastric pacing remains limited in clinical practice. In the stomach, omnipresent bioelectrical events known as slow-waves are responsible for coordinating motility that aids digestion. Functional motility diseases, such as gastroparesis, chronic unexplained nausea and vomiting, and functional dyspepsia, are associated with slow-wave dysrhythmias. The use of external electrical impulses to correct disordered cardiac rhythms is well established. Similar techniques have been assessed in the gastrointestinal (GI) field, from low energy/high-frequency (stimulation) to high energy/low frequency (pacing) protocols. High-frequency stimulation targets the neural pathways. Enterra (Medtronic, Minneapolis, MN) is the only clinical device currently available for gastric stimulation that uses high-frequency neuromodulation protocols, but does not correct dysrhythmias. Pacing is an attractive therapeutic approach to revert slow-wave abnormalities. However, there are currently no clinical gastric pacing devices in active use. Unlike cardiac pacing the application and performance of electrical pacing in the GI tract are not well understood and not widely used in clinical practice. A wide range of methods and protocols have been utilised in clinical research without the optimisation of pacing parameters, such as electrode type, location, and impulse properties. One of the barriers to the standardisation, optimisation, and development of gastric electrical pacing is that most previous gastric pacing studies utilised low-resolution recording techniques to assess the slow-wave responses to the different combinations of pacing parameters, where few recording electrodes were sparsely placed around the pacing site. Although sparse recording provides local measurements of slow-wave frequency and amplitude, it is unable to track, classify, and quantify the slow-wave activation sequences in spatiotemporal detail. Therefore, this approach may not have been sufficiently accurate to evaluate the effect of gastric pacing on the entrainment and propagation of the slow-waves. In the last decade, HR mapping techniques have been utilised to quantify and classify normal and abnormal slow-wave propagation patterns. The joint application of pacing and HR mapping provides a new analytical framework to investigate dysrhythmia and evaluate the benefits of gastric pacing as a potential therapeutic device.....
dc.publisher ResearchSpace@Auckland en
dc.relation.ispartof PhD Thesis - University of Auckland en
dc.relation.isreferencedby UoA en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title New Foundations for Pacing the Stomach
dc.type Thesis en
thesis.degree.grantor The University of Auckland en
thesis.degree.level Doctoral en
thesis.degree.name PhD en
dc.date.updated 2020-12-14T01:26:38Z
dc.rights.holder Copyright: The author en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
dc.identifier.wikidata Q112200702


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics