Air displacement plethysmography (pea pod) in full-term and pre-term infants: a comprehensive review of accuracy, reproducibility, and practical challenges.

Show simple item record

dc.contributor.author Mazahery, Hajar
dc.contributor.author von Hurst, Pamela R
dc.contributor.author McKinlay, Christopher JD
dc.contributor.author Cormack, Barbara E
dc.contributor.author Conlon, Cathryn A
dc.coverage.spatial England
dc.date.accessioned 2021-09-22T00:01:48Z
dc.date.available 2021-09-22T00:01:48Z
dc.date.issued 2018-1
dc.identifier.citation Maternal health, neonatology and perinatology 4:12 Jan 2018
dc.identifier.issn 2054-958X
dc.identifier.uri https://hdl.handle.net/2292/56620
dc.description.abstract Air displacement plethysmography (ADP) has been widely utilised to track body composition because it is considered to be practical, reliable, and valid. Pea Pod is the infant version of ADP that accommodates infants up to the age of 6 months and has been widely utilised to assess the body composition of full-term infants, and more recently pre-term infants. The primary goal of this comprehensive review is to 1) discuss the accuracy/reproducibility of Pea Pod in both full- and pre-term infants, 2) highlight and discuss practical challenges and potential sources of measurement errors in relation to Pea Pod operating principles, and 3) make suggestions for future research direction to overcome the identified limitations.
dc.format.medium Electronic-eCollection
dc.language eng
dc.publisher Springer Science and Business Media LLC
dc.relation.ispartofseries Maternal health, neonatology and perinatology
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher.
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm
dc.rights.uri https://www.biomedcentral.com/about/policies/license-agreement
dc.rights.uri https://creativecommons.org/licenses/by/4.0/legalcode
dc.subject ADP
dc.subject Air displacement plethysmography
dc.subject Body composition
dc.subject Full-term
dc.subject Infant
dc.subject Pea pod
dc.subject Pre-term
dc.subject 1117 Public Health and Health Services
dc.subject Pediatric
dc.title Air displacement plethysmography (pea pod) in full-term and pre-term infants: a comprehensive review of accuracy, reproducibility, and practical challenges.
dc.type Journal Article
dc.identifier.doi 10.1186/s40748-018-0079-z
pubs.issue 1
pubs.begin-page 12
pubs.volume 4
dc.date.updated 2021-08-11T01:26:50Z
dc.rights.holder Copyright: The author en
pubs.author-url https://www.ncbi.nlm.nih.gov/pubmed/29951209
pubs.publication-status Published
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype review-article
pubs.subtype Review
pubs.subtype Journal Article
pubs.elements-id 754744
dc.identifier.eissn 2054-958X
dc.identifier.pii 79
pubs.number 12
pubs.online-publication-date 2018-6-20


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics