dc.description.abstract |
The development of cost effective minimally-invasive seismic retrofi t techniques is required for clay brick unreinforced masonry (URM) buildings because of their recognised poor seismic performance. A laboratory-based xperimental study with well defi ned but artificial boundary conditions, which utilises constituent construction materials that replicate the material properties of masonry found in historic URM buildings, is currently addressing this need. The purpose of this study is to investigate the performance of near-surface mounted (NSM) carbon fibre reinforced polymer (CFRP) strips as a seismic retrofit solution for out-of-plane lateral loading of the walls in URM buildings. In addition, five retrofi tted URM walls located in four different buildings were tested in-situ by applying outof- plane loading, to complement the laboratory-based study. Testing confi rmed that the NSM CFRP retrofit technique is an excellent minimally-invasive and cost effective option for seismic strengthening of URM buildings. Provisional details of the design methodology for the NSM CFRP retrofit technique, and laboratory and in-situ test results are reported. Two recent projects that implemented the NSM CFRP technique are also briefly presented. |
en |
dc.relation.ispartof |
Journal of the Structural Engineering Society of New Zealand |
en |
dc.rights |
Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. |
en |
dc.rights.uri |
https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm |
en |
dc.source.uri |
http://sesoc.org.nz/Journals/abstracts.cfm?id=43 |
en |
dc.title |
Out-of-Plane Strengthening of Unreinforced Masonry Walls Using Near Surface Mounted Fibre Reinforced Polymer Strips |
en |
dc.type |
Journal Article |
en |
pubs.issue |
2 |
en |
pubs.begin-page |
91 |
en |
pubs.volume |
23 |
en |
dc.rights.holder |
Copyright: 2010 SESOC Journal |
en |
pubs.end-page |
103 |
en |
pubs.publication-status |
Published |
en |
dc.rights.accessrights |
http://purl.org/eprint/accessRights/RestrictedAccess |
en |
pubs.elements-id |
164970 |
en |
pubs.org-id |
ENGFAC - Faculty of Engineering |
en |
pubs.org-id |
CIVENV - Civil & Environmental Engineer |
en |