A method for assessment of blood volume parameters in pregnant sheep using fluorescein-labelled dextran

Show simple item record

dc.contributor.author Rumball, Christopher en
dc.contributor.author Van Zijl, P en
dc.contributor.author Rutland, MD en
dc.contributor.author Bloomfield, Francis en
dc.contributor.author Harding, Jane en
dc.date.accessioned 2011-02-03T02:30:34Z en
dc.date.issued 2008-01 en
dc.identifier.citation PLACENTA 29(1):15-19 Jan 2008 en
dc.identifier.issn 0143-4004 en
dc.identifier.uri http://hdl.handle.net/2292/6309 en
dc.description.abstract The assessment of blood volume parameters in clinical and research settings has been limited by methods that involve radioactivity, complex assays or are unreliable. We aimed to design a method for measuring blood volume parameters that was non-radioactive, simple, cheap and reliable. We have used a commercially available fluorescein-labelled 250 kDa dextran, a large inert molecule, and have measured dilution of this through the intravascular space of pregnant ewes. From this estimation of plasma volume and measured hematocrit, we have calculated blood volume and red cell volume. The blood volume results are 6% lower than those obtained using radiolabelled red cells, but there is no significant difference in red cell volume between methods. The coefficient of variation for repeated measurements of plasma volume measurements is 3.8%. This is a simple, reliable, cheap and non-radioactive method for estimating blood volume parameters in pregnant sheep, and may prove useful in other settings. (c) 2007 Elsevier Ltd. All rights reserved. en
dc.language EN en
dc.publisher W B SAUNDERS CO LTD en
dc.relation.ispartofseries PLACENTA en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained from http://www.sherpa.ac.uk/romeo/issn/0143-4004/ en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.subject plasma volume en
dc.subject red cell volume en
dc.subject radiolabelled red cells en
dc.subject pregnancy en
dc.subject ovine en
dc.subject PLASMA-VOLUME en
dc.subject RED-CELL en
dc.subject RESPONSES en
dc.subject RATS en
dc.title A method for assessment of blood volume parameters in pregnant sheep using fluorescein-labelled dextran en
dc.type Journal Article en
dc.identifier.doi 10.1016/j.placenta.2007.09.002 en
pubs.issue 1 en
pubs.begin-page 15 en
pubs.volume 29 en
dc.rights.holder Copyright: 2007 Elsevier Ltd. en
dc.identifier.pmid 17953987 en
pubs.end-page 19 en
pubs.publication-status Published en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Article en
pubs.elements-id 80693 en
pubs.org-id Liggins Institute en
pubs.org-id LiFePATH en
pubs.record-created-at-source-date 2010-09-01 en
pubs.dimensions-id 17953987 en


Files in this item

There are no files associated with this item.

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics