Assessment of timber floor diaphragms in historic unreinforced masonry buildings

Show simple item record

dc.contributor.author Wilson, AW en
dc.contributor.author QUENNEVILLE, PJH en
dc.contributor.author Ingham, Jason en
dc.coverage.spatial Lisbon, Portugal en
dc.date.accessioned 2011-08-10T22:09:33Z en
dc.date.issued 2011 en
dc.identifier.citation International conference on structural health assessment of timber structures, Lisbon, Portugal, 16 Jun 2011 - 17 Jun 2011. Proceedings of the International conference on structural health assessment of timber structures. 2011 en
dc.identifier.uri http://hdl.handle.net/2292/7219 en
dc.description.abstract Unreinforced masonry (URM) buildings outside of Europe were typically constructed with rigid clay brick perimeter walls, and comparatively flexible timber floor diaphragms. URM construction represents the predominant architectural heritage of many nations but the preservation of these buildings in seismically active regions is threatened due their well established inadequacy to withstand earthquakes. Timber floor diaphragms are widely recognized to have significant impact on the overall seismic response of URM structures, and the accurate assessment of diaphragms is therefore crucial during the seismic assessment and retrofit of URM buildings. NZSEE (2006) - Assessment and improvement of the structural performance of buildings in earthquakes, and ASCE 41-06 (2007) – Seismic rehabilitation of existing buildings represent the current state-of-the-art in seismic assessment but the validity of the procedures associated with timber diaphragm performance remains uncertain, and a review of their application and accuracy is required. As part of a wider research program, a series of full-scale diaphragm tests were performed to generate the much needed data to critique the current desktop procedures. In this contribution, the NZSEE and ASCE 41-06 procedures are used to predict full-scale diaphragm performance and are compared against experimentally determined values. It was found that inconsistency exists between the two assessment documents with considerable differences found in strength, stiffness and ductility predictions. The procedures published in NZSEE and ASCE 41-06 require updated and representative values, and to include provisions to address the highly orthotropic nature of diaphragms that was identified from testing. It is also believed that these documents should be harmonized to ensure that transparency and consistency exists between international assessment procedures. en
dc.description.uri http://shatis11.lnec.pt/ en
dc.relation.ispartof International conference on structural health assessment of timber structures en
dc.relation.ispartofseries Proceedings of the International conference on structural health assessment of timber structures en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.subject timber floor diaphragms en
dc.subject seismic assessment en
dc.subject heritage en
dc.title Assessment of timber floor diaphragms in historic unreinforced masonry buildings en
dc.type Conference Item en
dc.rights.holder Copyright: the author en
pubs.finish-date 2011-06-17 en
pubs.publication-status Published en
pubs.start-date 2011-06-16 en
dc.rights.accessrights http://purl.org/eprint/accessRights/OpenAccess en
pubs.subtype Proceedings en
pubs.elements-id 218391 en
pubs.org-id Engineering en
pubs.org-id Civil and Environmental Eng en
pubs.record-created-at-source-date 2011-08-11 en


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics