dc.description.abstract |
This paper presents a novel method of inductively powering an implantable telemetry device over a large area. The system is based around an array of individually tuned series resonant circuits distributed across a charging pad. By varying the frequency of the driving voltage, the location of the charging field is changed. Presented are a method of controlling the resonant frequency and techniques for determining the geometry of the charging pad. Results from a nine coil system operating between 97 kHz and 209 kHz are given which can deliver 100 mW to an implanted telemeter at a height of 5cm above the charging pad. |
en |
dc.relation.ispartof |
29th IEEE Engineering in Medicine and Biology Conference |
en |
dc.rights |
Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. |
en |
dc.rights.uri |
https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm |
en |
dc.subject |
sensor-based systems for monitoring communication and minimum power consumption |
en |
dc.title |
Powering implantable telemetry devices from localized magnetic fields |
en |
dc.type |
Conference Item |
en |
pubs.begin-page |
2331 |
en |
dc.rights.holder |
Copyright: IEEE |
en |
dc.identifier.pmid |
18002459 |
en |
pubs.author-url |
https://embs.papercept.net/conferences/scripts/abstract.pl?ConfID=6&Number=1197http://ieeexplore.ieee.org.ezproxy.auckland.ac.nz/search/srchabstract.jsp?arnumber=4352793&isnumber=4352185&punumber=4352184&k2dockey=4352793@ieeecnfs&query=%28%28powering+implantable+telemetry+devices+from+localized+magnetic+fields%29%3Cin%3Eti+%29&pos=0 |
en |
pubs.end-page |
2335 |
en |
pubs.place-of-publication |
Lyon |
en |
dc.rights.accessrights |
http://purl.org/eprint/accessRights/RestrictedAccess |
en |
pubs.elements-id |
92495 |
en |
pubs.org-id |
Bioengineering Institute |
en |
pubs.org-id |
ABI Associates |
en |
pubs.org-id |
Engineering |
en |
pubs.org-id |
Department of Electrical, Computer and Software Engineering |
en |
pubs.org-id |
Engineering Science |
en |
pubs.org-id |
Medical and Health Sciences |
en |
pubs.org-id |
Medical Sciences |
en |
pubs.org-id |
Physiology Division |
en |
pubs.org-id |
Science |
en |
pubs.org-id |
Science Research |
en |
pubs.org-id |
Maurice Wilkins Centre (2010-2014) |
en |
pubs.record-created-at-source-date |
2010-09-01 |
en |
pubs.dimensions-id |
18002459 |
en |