Topographical Analysis of the Retina Using Visual Evoked Response Imaging System (Veris)

Show simple item record

dc.contributor.advisor Jacobs, R. en
dc.contributor.advisor Yap, M.K. en
dc.contributor.author Mohidin, Norhani en
dc.date.accessioned 2007-07-11T03:41:50Z en
dc.date.available 2007-07-11T03:41:50Z en
dc.date.issued 1998 en
dc.identifier THESIS 98-301 en
dc.identifier.citation Thesis (PhD--Optometry)--University of Auckland, 1998 en
dc.identifier.uri http://hdl.handle.net/2292/879 en
dc.description Full text is available to authenticated members of The University of Auckland only. en
dc.description.abstract The Visual Evoked Response Imaging System (VERIS) was introduced by Sutter and Tran (1992) and presents a new method of recording and analyzing the multifocal electroretinogram (ERG). Because it is new, several issues need to be addressed for the method to be useful in clinical application. The purpose of this thesis is to address some of these issues which include: i) type of electrodes used in the VERIS system, ii) effect of patient age on the multifocal electroretinogram, iii) sensitivity of the VERIS system in detecting abnormal retinal conditions. Four different electrode types were used to record the multifocal ERG and responses from different areas of the retinal field were compared. The areas were divided into a central area and five adjacent concentric rings around the centre. The JET contact lens electrode and the gold foil electrode produced the highest amplitude response densities for the central area and the 2nd concentric ring which were significantly higher than the amplitude densities for the DTL thread and carbon-glide electrodes. For the 1st concentric ring however the amplitude response density for the JET contact lens was higher than the amplitude densities of all the other electrodes. For all electrodes, no significant differences in amplitude densities obtained from the 3rd to 5th concentric rings were found. en
dc.language.iso en en
dc.publisher ResearchSpace@Auckland en
dc.relation.ispartof PhD Thesis - University of Auckland en
dc.relation.isreferencedby UoA9984183814002091 en
dc.rights Restricted Item. Available to authenticated members of The University of Auckland. en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.title Topographical Analysis of the Retina Using Visual Evoked Response Imaging System (Veris) en
dc.type Thesis en
thesis.degree.discipline Optometry en
thesis.degree.grantor The University of Auckland en
thesis.degree.level Doctoral en
thesis.degree.name PhD en
dc.rights.holder Copyright: The author en
dc.identifier.wikidata Q112552613


Files in this item

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics