Measuring the Repeatability of Simulated Physiology in Simulators

Show simple item record

dc.contributor.author Cumin, David en
dc.contributor.author Chen, C en
dc.contributor.author Merry, Alan en
dc.date.accessioned 2016-01-29T03:13:10Z en
dc.date.issued 2015-12 en
dc.identifier.citation Simulation in Healthcare, 2015, 10 (6), pp. 336 - 344 (9) en
dc.identifier.issn 1559-713X en
dc.identifier.uri http://hdl.handle.net/2292/28145 en
dc.description.abstract In simulation, it may be important in some instances that the physiologic responses to given interventions are substantially repeatable. However, there is no agreed approach to evaluating the repeatability of simulators. We therefore aimed to develop such an approach.In repeated simulations, we evaluated the physiologic responses to 7 simple clinical interventions generated by a METI (Medical Education Technologies Incorporated, Sarasota, FL) HPS (Human Patient Simulator) simulator in connected and disconnected states and the screen-based Anesoft Anesthesia Simulator. For a selection of variables, we calculated 3 objective measures of similarity (root mean squared error, median performance error, and median absolute performance error). We also calculated divergence over time and compared 3 preprocessing techniques to reduce the effect of clinically irrelevant phase and frequency differences (simple phase shift, complex phase shift, and dynamic time warping).We collected data from more than 85 hours of simulation time from 255 simulations. The Anesoft physiologic responses were reproduced exactly in each simulation for all variables and interventions. Minor divergence was present between the time series generated with the METI HPS in the connected state but not in the disconnected state. The METI HPS showed some variation between simulations in the raw data. This was most usefully quantified using median absolute performance error as an indicator and was substantially reduced by preprocessing, particularly with dynamic time warping.The repeatability of the physiologic response of model-controlled simulators to simple standardized interventions can be evaluated by considering divergence over time and the median absolute performance error of individual or pooled variables, but data should be preprocessed to eliminate irrelevant phase and frequency offsets in some variables. Dynamic time warping is an effective method for this purpose. en
dc.description.uri http://www.ncbi.nlm.nih.gov/pubmed/26335561 en
dc.format.medium Print en
dc.language English en
dc.publisher Society for Simulation in Healthcare / Lippincott Williams & Wilkins en
dc.relation.ispartofseries Simulation in Healthcare en
dc.rights Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated. Previously published items are made available in accordance with the copyright policy of the publisher. Details obtained from http://www.sherpa.ac.uk/romeo/issn/1559-2332/ en
dc.rights.uri https://researchspace.auckland.ac.nz/docs/uoa-docs/rights.htm en
dc.subject Physiology-modeling en
dc.subject Modeling en
dc.subject Training en
dc.title Measuring the Repeatability of Simulated Physiology in Simulators en
dc.type Journal Article en
dc.identifier.doi 10.1097/SIH.0000000000000098 en
pubs.issue 6 en
pubs.begin-page 336 en
pubs.volume 10 en
dc.rights.holder Copyright: Society for Simulation in Healthcare / Lippincott Williams & Wilkins en
dc.identifier.pmid 26335561 en
pubs.end-page 344 en
pubs.publication-status Published en
dc.rights.accessrights http://purl.org/eprint/accessRights/RestrictedAccess en
pubs.subtype Article en
pubs.elements-id 501328 en
pubs.org-id Medical and Health Sciences en
pubs.org-id School of Medicine en
pubs.org-id Anaesthesiology en
dc.identifier.eissn 1559-713X en
pubs.record-created-at-source-date 2016-01-29 en
pubs.dimensions-id 26335561 en


Files in this item

There are no files associated with this item.

Find Full text

This item appears in the following Collection(s)

Show simple item record

Share

Search ResearchSpace


Browse

Statistics